- Number of inputs: 4
- Number of outputs: 4 (open-collector outputs – 50mA / 12V DC)
- Standby current consumption: 80mA
- Maximum current consumption: 300mA
- Telephone line emulation for connecting the alarm control panel’s telephone communicator
- (supports the Contact ID protocol for communication between the dialler and the alarm control panel)
- Dedicated AC input for monitoring the presence of AC voltage (max. 18V AC, 50Hz)
- Data transmission: 2G/4G technology
- Antenna: included with the module
- Programming port: mini USB (using an adapter)
- Supply voltage: 12V ± 15%
- Operating temperature range: -20°C to +55°C
- Dimensions: 80 × 57 × 12 mm
- Transmission to the receiving station via SMS, GPRS/LTE
- Supported communication protocols:
- PULSON (UDP)
- SIA (TCP) – with optional encryption, support for the Contact ID protocol
- Notifications to up to 10 users via SMS (message length up to 32 characters)
- Control of outputs via CLIP/SMS (up to 10 users)
- Ability to control outputs via SMS/CLIP (10 users)
- Built-in temperature sensor
- Event log: up to 65,535 entries
Nadajnik STD-4G
68,88 € gross
1 In Stock- Protocols supported by the transmitter for communication:
- PULSON protocol (UDP),
- SIA protocol (TCP) (including encryption), and
- the Contact ID protocol is used.
- Notifications to a maximum of 10 users via SMS (32 characters per message).
- Control of outputs via CLIP / SMS for up to 10 users.
- Enables control of outputs via SMS / CLIP (10 users).
- It has a temperature sensor.
- Built-in event log with a capacity of 65,535 entries.
1 in stock
- DPD across Europe & worldwide — free in the EU from 1000,00 € (ex. VAT)
- Official BCS e-commerce Business Partner
- Technical support
| Product | Nadajnik STD-4G |
|---|